Water-coil cooling
The water coil provides cooling. The heat pump can contribute additional output under the selected sequence.
Transform existing two-pipe buildings with a focused change at the room level. PerFitTech brings the equipment, controls, and engineering together in one coordinated modernization package.
Preserve the building’s two-pipe infrastructure and concentrate the transformation where comfort is delivered. We engineer the room-level equipment, connections, and controls into a revolutionary alternative to conventional four-pipe upgrades.
Keep the supply and return infrastructure. Coordinate local connections, flow, and balancing around the new terminals.
Engineer around existing chilled- and hot-water generation, with plant and loop adjustments defined in the project scope.
Plan room-by-room modernization around occupied operations, delivering the upgrade without business disruption.
The engineering work turns a focused intervention into a repeatable installation package, coordinated with the owner’s engineer, facilities team, and installation trades.
Design output: Room-type equipment schedule and selection criteria.
Design output: Hydronic criteria and local connection details.
Design output: Electrical requirements and protection schedule.
Design output: Room installation details and phasing plan.
Design output: Coordinated performance and project requirements.
Design output: Controls narrative and commissioning package.
PMAC, the in-room thermostat and dual-sensor wireless network, and local and cloud servers work together as one PerFitTech package—from individual room comfort to property-level operating intelligence.
The hybrid fan coil and heat pump deliver room-level heating and cooling through the existing water loop.
The room’s comfort command point brings temperature sensing, setpoints, and occupant interaction together.
The dual-sensor wireless network connects room conditions to the property’s control and operating strategy.
Local and cloud servers support property-wide visibility, data collection, analytics, and connected service.
Room sequencesSetpoints, deadbands, fan behavior, occupancy response, and compressor protection.
Interlocks & alarmsWater circulation, drain safety, protective shutdowns, and actionable fault reporting.
Property integrationCommands, status, trends, permissions, and the required BMS or PMS interfaces.
CommissioningVerify room operation, communications, alarm routing, and operator handover.
Protocol support and available points are defined for the selected controller and gateway. The project’s controls narrative establishes BACnet, Modbus, BMS, and PMS integration requirements.
Useful manufacturer guidance for understanding operation and coordinating a design. PerFitTech brings the selected equipment and integration details together for your project.
Operating principles, product families, floor-unit reference data, and installation guidance.
How the water coil and heat pump respond to loop conditions and room demand.
Local modes, thermostat interfaces, pump interlock, reporting, and protective functions.
Manufacturer reference data is model- and market-specific. Use current project submittals for final capacities, dimensions, electrical requirements, controls, and equipment selection.